Five key considerations in selecting chiller for your building

Published by firstgreen on

When selecting a chiller for your building, there are several considerations that you should keep in mind. Chillers are an essential component of air conditioning systems, and their efficiency and capacity can have a significant impact on the overall energy consumption and operating costs of the building. In this article, we will discuss some of the key considerations in selecting a chiller for your building.

Efficiency Requirements The first consideration in selecting a chiller for your building is efficiency. Chillers are rated based on their Coefficient of Performance (COP) or Integrated Part Load Value (IPLV). The COP is the ratio of cooling output to energy input, while the IPLV is an average efficiency rating that takes into account the chiller’s performance at different load conditions. The minimum efficiency requirements for chillers are typically specified by building codes and standards such as ANSI/AHRI 550/590 and BEE Standards and Labeling Program. To comply with these standards, you should select a chiller that meets or exceeds the minimum efficiency requirements.

Cooling Load The cooling load of your building is another important consideration when selecting a chiller. The cooling load is the amount of cooling capacity that is required to maintain the desired indoor temperature and humidity levels. The cooling load of your building can be affected by factors such as the building’s orientation, insulation, and occupancy. It’s important to select a chiller that has the appropriate capacity to meet the cooling load of your building. If the chiller is too small, it may not be able to maintain the desired indoor conditions, while if it’s too large, it may result in unnecessary energy consumption and operating costs.

Chiller Type There are two main types of chillers: air-cooled and water-cooled. Air-cooled chillers are typically used in smaller buildings or in situations where water is not readily available. Water-cooled chillers are typically used in larger buildings or in situations where water is readily available. The choice of chiller type will depend on factors such as the cooling load, space availability, and environmental conditions.

Maintenance and Serviceability Maintenance and serviceability are important considerations when selecting a chiller for your building. Regular maintenance is essential to ensure the optimal performance and efficiency of the chiller. You should select a chiller that is easy to maintain and service, with accessible components and controls. You should also consider the availability of service technicians and replacement parts.

Cost and Budget Finally, cost and budget are important considerations when selecting a chiller for your building. Chillers can be a significant investment, and you should consider the initial cost as well as the long-term operating costs when selecting a chiller. You should also consider factors such as financing options, rebates, and incentives that may be available to help offset the cost of the chiller.

ConsiderationDetails
Minimum EfficiencyChillers must meet or exceed the minimum efficiency requirements as per ANSI/AHRI 550/590.
Cooling LoadAir-cooled chillers are allowed for buildings with cooling load less than 530 kW.
The number of air-cooled chillers is restricted to 33% of the total installed capacity for buildings with cooling load equal to or greater than 530 kW, unless mandated by the authority having jurisdiction.
BEE StandardsMinimum efficiency requirements as per the BEE Standards and Labeling Program take precedence over minimum requirements under ANSI/AHRI.
ECBC ComplianceTo comply with ECBC, both the Coefficient of Performance (COP) and Integrated Part Load Value (IPLV) requirements must be met.
ECBC+ and SuperECBCTo comply with ECBC+ and SuperECBC, either the COP or IPLV of respective efficiency level must be met.

In conclusion, selecting a chiller for your building requires careful consideration of efficiency requirements, cooling load, chiller type, maintenance and serviceability, and cost and budget. By selecting the right chiller for your building, you can ensure optimal performance and efficiency, while minimizing energy consumption and operating costs.