Skip to content

2026-11-27

Why matching module counts can hide a structure mismatch

A procurement schedule may contain a mix of full and half tables, while a preliminary layout uses full tables throughout. The total number of modules can agree closely even though the mounting structure order needs a different mix.

Count like for like

Separate each table type and multiply by the number of modules it actually carries. In a two-portrait arrangement, a 2 × 56 table holds 112 modules and a 2 × 28 table holds 56. Substituting one full table for two half tables preserves module count but changes the number and geometry of assemblies.

Review the boundary rows

Look at short rows around exclusions and changes of direction. These are the places where a smaller assembly may fit. Confirm the mounting structure drawing and available table types before using the layout to release an order.

Explore Firstgreen’s solar layout quantity and boq reconciliation service.

Leave a Reply

Your email address will not be published. Required fields are marked *